press information / news

Imaging
23.04.2018

Fluorescent dye could enable sharper biological imaging

Recently, Dr. Oliver Bruns joined the new Helmholtz Pioneer Campus, where he aims to visualize processes in living organisms. Together with his former colleagues from the Massachusetts Institute of Technology (MIT), he demonstrates how this might succeed. In a recent 'PNAS' publication they combined an already approved fluorescent dye with latest technology and received remarkable images.

A comparison of blood vessels imaged with short-wave fluorescence imaging (right) and near-infrared fluorescence imaging (left). Both images rely on a fluorescent dye called ICG, but the vessels can be seen more clearly with short-wave fluorescence imaging. © Oliver Bruns/Massachusetts Institute of Technology

Fluorescence imaging is widely used for visualizing biological tissues such as the back of the eye, where signs of macular degeneration can be detected. It is also commonly used to image blood vessels during reconstructive surgery, allowing surgeons to make sure the vessels are properly connected.

For these procedures, as well as others now in clinical trials, such as imaging tumors, researchers use a portion of the light spectrum known as the near-infrared (NIR) — 700 to 900 nanometers, just beyond what the human eye can detect. A dye that fluoresces at this wavelength is administered to the body or tissue and then imaged using a specialized camera. Researchers have shown that light with wavelengths greater than 1,000 nanometers, known as short-wave infrared (SWIR), offers much clearer images than NIR, but there are no FDA-approved fluorescence dyes with peak emission in the SWIR range.

The team of researchers at MIT and Massachusetts General Hospital has now taken a major step toward making SWIR imaging widely available. They have shown that an FDA-approved, commercially available dye now used for near-infrared imaging also works very well for short-wave infrared imaging. “What we found is that this dye, which has been approved since 1959, is really the best, the brightest fluorophore that we know of at this point for imaging in the short-wave infrared,” says Moungi Bawendi, the Lester Wolf Professor of Chemistry at MIT. “Now clinicians can start to try short-wave imaging for their applications because they already have a fluorophore which is approved for use in humans.”

Imaging this dye with a camera that detects short-wave infrared light could allow doctors and researchers to obtain much better images of blood vessels and other body tissues for diagnosis and research. Bawendi and former MIT research scientist Oliver Bruns are the senior authors of the study. The paper’s lead authors are MIT graduate students Jessica Carr and Daniel Franke.

Cutting through the fog

The dye that the researchers used in this study, known as indocyanine green (ICG), fluoresces most strongly around 800 nanometers, which falls within the near-infrared range. When injected into the body, it travels through the bloodstream, making it ideal for angiography (the visualization of blood flowing through vessels). Some robot-assisted surgical systems have incorporated NIR fluorescence imaging to help visualize blood vessels and other anatomical features.

The team discovered ICG’s usefulness for SWIR imaging somewhat serendipitously as part of a control experiment for another paper. However, they have been interested in developing fluorophores for SWIR imaging before, because SWIR offers better contrast and clarity than NIR. Light with shorter wavelengths tends to scatter off of imperfections in objects that it strikes, but as wavelengths become longer, scattering is greatly reduced.

“In the near-infrared, a lot of the features you see in tissue can look foggy, and once you move into the short-wave infrared, the image clears up and everything becomes sharp,” the new HPC scientist Bruns says. Short-wave infrared can also penetrate deeper into tissue, although calculating exactly how far is a complicated process, the researchers say, because it depends on the size of the structure being viewed and the field of view of the microscope. In the new study, the researchers were able to see several hundred micrometers into tissue using a regular fluorescence microscope. Normally, this depth can be reached only with two-photon microscopy, a much more complicated and expensive type of imaging.

“We found that short-wave infrared is particularly useful for imaging small objects that are on top of a large background, so when you want to do angiography of small vessels, or capillaries, that’s significantly easier in the short-wave infrared than in the near-infrared,” Franke says.

In their study, the researchers further explored ICG and showed that it gives a stronger signal than other SWIR dyes now in development. Previous studies of ICG had focused on its emission around 800 nanometers, where it fluoresces the brightest, so no one had observed that the dye also produced a strong signal at longer wavelengths. Though it doesn’t fluoresce efficiently in the shortwave-infrared range, ICG absorbs so much light that if even a small percentage is emitted as fluorescent light, the signal is brighter than that produced by other SWIR dyes.

The researchers also found that ICG is bright enough that it can produce images quickly, which is important for capturing motion. “If you don’t have a strong enough signal, it slows down how long it takes to take the image, so you can’t use it for imaging motion such as blood flowing or the heart beating,” Carr says. The research team is now further investigating why ICG works so well for shortwave-infrared imaging, and is trying to identify the optimal wavelength for its use, which they hope will help them determine the best applications for this kind of imaging. They are also working with other labs to develop dyes that are similar to ICG and might work even better.

Further Information

Background:
To do shortwave-infrared imaging, research labs and hospitals would need to switch from the silicon cameras now used for NIR imaging to an indium gallium arsenide (InGaAs) camera. Until recently, these cameras have been prohibitively expensive, but the prices have been coming down in the past several years. The research was funded by the National Institutes of Health through the Laser Biomedical Research Center; MIT through the Institute for Soldier Nanotechnologies; the National Science Foundation; and the Department of Energy Office of Science.

Original Publication:
Carr JA. Et al. (2018): Shortwave infrared fluorescence imaging with the clinically approved near-infrared dye indocyanine green. Proceedings of the National Academy of Sciences, DOI: 10.1073/pnas.1718917115

As German Research Center for Environmental Health, Helmholtz Zentrum München pursues the goal of developing personalized medical approaches for the prevention and therapy of major common diseases such as diabetes mellitus, allergies and lung diseases. To achieve this, it investigates the interaction of genetics, environmental factors and lifestyle. The Helmholtz Zentrum München has about 2,300 staff members and is headquartered in Neuherberg in the north of Munich. Helmholtz Zentrum München is a member of the Helmholtz Association, a community of 18 scientific-technical and medical-biological research centers with a total of about 37,000 staff members. 

We use cookies to improve your experience on our Website. We need cookies to continuously improve the services, to enable certain features and when embedding services or content of third parties, such as video player. By using our website, you agree to the use of cookies. We use different types of cookies. You can personalize your cookie settings here:

Only cookies permitted that are required for the basic functionality of our websites.
Permit cookies that help us to analyse the page views and user behavior on our websites. We only use this information for improving our services.
Permit embedded content and cookies from third party providers. This setting enables the full use of our web services (e.g. displaying videos).
Please find more information in our privacy statement.

There you may also change your settings later.